Outline
Conductivity Analyzer(DWA-2000A Controller) has built-in microprocessor and DIN96 Standard size for install on-the-spot. It is simple and rapid indication controller to measure conductivity values constantly, and it is designed for easily applicable to any process line such as boiler feed water, food industry, chemical industry, power plants and plating applications.
This compact case has the built-in high brightness 7-Segment, manual/auto calibration, sensor automatic temperature compensation, Relay contact output(2 phases), 1.6Km COMMUNICATION MODEM interface function. And this product actualizes LOW-COST to make the customer’s satisfaction and faith.
Conductivity Analyzer(DWA-2000A Controller) includes Isolation function and all the circuit needs in 4~20mA Output and Transmission to provide faithful data in any monitoring process and controlling place.
Function/Features
● DIN Standard 96 Size
● Relay contact High, Low 2-Output
● Real Time Measurement Value Transmission 4~20mA
● Long Distance Communication DC Power Modem(Option)
● Water-jet, Air-jet, Ultrasonic Wave, and Medicinal fluid Cleaning
of relay contact output
● Automatic temperature compensation
● Automatic/Manual calibration.
● Compatible with electrodes with various cell constant 0.01, 0.1, 1, 10
Specification
|
Classification
|
Product Specification
|
|
Product Name
|
Online Conductivity Analyzer
|
|
Model Name
|
DWA-2000A
|
|
Measurement Range
|
0~10㎲/cm, 0~100㎲/cm, 0~1mS/cm, 0~10mS/cm, or User Spec’
|
|
Power
|
AC100V/AC220V 50/60Hz ±10% 3VA
|
|
Display
|
Measurement Indicate(7-Segment)
Temperature Indicate(7-Segment), Signal Indicate(LED)
|
|
Keypad
|
Membrane Keypad 4 keys
|
|
Temperature Range
|
Temperature : -25℃ ~ 70℃
Relative Humidity : Max. 90%(Non-condensing)
|
|
Accuracy
|
±1 % of Full Scale
|
|
Repeatability Reproducibility
|
±1 % of Full Scale
|
|
Response
|
5 sec (90% saturation)
|
|
Contact
|
High, Low(2 Outputs)
Water-jet, Air-jet, Ultrasonic Wave, Medicinal fluid cleaning(Option)
|
|
Signal Output
|
DC : Isolated 0~20, 0~24, 4~20mA_Option
Digital Interface: Isolated RS232C/DC POWER MODEM_Option
|
|
Temperature Compensation
|
Auto/Manual Temperature Compensation(RTD/PT1000Ω/PT100Ω/NTC10K)
|
|
Cell Constant Range
|
0.01, 0.1, 1(STD), 10 Selection Setting
|
|
Electrode Type
|
2 Electrodes, Ordering Information
|
|
Condition
|
Measurement Pressure - 0~10kgㆍf/cm2
Measurement Flow rate - 0.5~1ℓ/min(Optimum condition)
|
|
Sensor Calibration
|
Auto/Manual Calibration
|
|
Enclosure Material
|
ABS
|
|
Enclosure Size
|
96(W)×96(H)×125(D)
|
|
Enclosure Structure
|
IP54, Outdoor installation structure
|
|
Enclosure Installation
|
Panel Wall Mounting
|
|
Weight
|
About 0.5Kg
|
|